Case: T09FR00780

Parcel: 12404032C


Addresses:

1423 E 1ST ST

Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
03/13/2009 VIOL - MEANS OF EGRESS Approved
02/27/2009 VIOL - MEANS OF EGRESS Violation 1008.1.8 Door operations. Except as specifically permitted
by this section egress doors shall be readily openable from
the egress side without the use of a key or special knowledge
or effort.

____Remove chains and locks from dining room doors. These locks are never allowed.
02/27/2009 VIOL - MEANS OF EGRESS Violation 1027.3 Exit sign illumination.

____Repair the following Exit Signs:
____Dining room.
____Warming kitchen.
02/27/2009 VIOL - MEANS OF EGRESS Violation 1027.5 Illumination emergency power.

____Repair the following Emergency Lighting Units:
____Warming kitchen.