Case: T09FR00729

Parcel: 137055220


Addresses:

1223 W IRVINGTON RD


Inspection Status: Violation

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T09FR00729

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Violation

Date Description Inspector Results Comments
02/23/2009 VIOL - MEANS OF EGRESS Violation 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.

___Remove keyed lock and sliding bolt mechanism from rear emergency exit , replace with approved locking mechanis.
02/23/2009 VIOL - MEANS OF EGRESS Violation 1027.3 Exit sign illumination. Exit signs shall be internally or externally illuminated. The face of an exit sign illuminated from an external source shall have an intensity of not less than 5 foot-candles. Internally illuminated signs shall provide equivalent luminance and be listed for the purpose.