Inspection Status: Violation
Inspection History: VIOL - MEANS OF EGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2009 | VIOL - MEANS OF EGRESS | Violation | 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ___Remove keyed lock and sliding bolt mechanism from rear emergency exit , replace with approved locking mechanis. |
|
| 02/23/2009 | VIOL - MEANS OF EGRESS | Violation | 1027.3 Exit sign illumination. Exit signs shall be internally or externally illuminated. The face of an exit sign illuminated from an external source shall have an intensity of not less than 5 foot-candles. Internally illuminated signs shall provide equivalent luminance and be listed for the purpose. |