Case: T09FR00612

Parcel: 117040500


Addresses:

628 N 4TH AV


Inspection Status: Violation

Inspection History: VIOL - INT.FINISH, DEC. MATL'S

Case Number - T09FR00612

Inspection Description - VIOL - INT.FINISH, DEC. MATL'S

Inspection Status - Violation

Date Description Inspector Results Comments
02/17/2009 VIOL - INT.FINISH, DEC. MATL'S Violation 807.1 General requirements. In occupancies in Groups A, E,
I and R-1 and dormitories in Group R-2, curtains, draperies,
hangings and other decorative materials suspended from walls
or ceilings shall meet the flame propagation performance criteria
of NFPA 701 in accordance with Section 806.2 or be
noncombustible.
807.1.2 Combustible decorative materials. The permissible
amount of decorative materials meeting the flame propagation
performance criteria of NFPA 701 shall not exceed
10 percent of the aggregate area of walls and ceilings.
807.2 Acceptance criteria and reports. Where required to be
flame resistant, decorative materials shall be tested by an
approved agency and meet the flame propagation performance
criteria of NFPA 701, or such materials shall be
noncombustible. Reports of test results shall be prepared in
accordance with NFPA 701 and furnished to the fire code official
upon request.

1) Remove all combustible decorative material inside the restaurant
and inside the permanent tent. This material does not meet the Fire
Code requirements.