Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 03/02/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE INSPECTION ITEM #6 FROM 12/17/09 2) RESCHEDULE WHEN ITEM IS COMPLETED 3) NEXT INSPECTION WITH NO PROGRESS WILL RESULT IN REINSPECTION FEE |
|
| 02/16/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection 1) #6 NOT COMPLETED 2) PLEASE PAY REFEE BEFORE NEXT INSPECTION |
|
| 02/08/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* 1) THERE IS NO ACCESS TO SITE |
|
| 01/28/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* 1) COMBINATION LEFT ON MESSAGE WOULD NOT OPEN LOCK BOX |
|
| 01/20/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE ITEM #6 2) INSTALL SMOKE DETECTOR IN HALL PER INSTRUCTIONS |
|
| 12/17/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LIGHTS AT FRONT PORCH TO BE WIRED PER CODE AND REQUIRE JUNCTION BOXES AT SPLICES 2) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED 3) INSTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS 4) HALLWAY SMOKE NOT INSTALLED PROPERLY 5) T & P LINE FOR WATER HEATER TO BE COPPER OR CPVC 6) NEW PANEL IN BEDROOM CLOSET NOT INSTALLED PER CODE 7) RESCHEDULE WHEN COMPLETE |