Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/03/2009 | ELECTRIC - SERVICE UPGRADE | Partial Approval | IVRS - Inspection :* 1) COMPLETE ITEM #2 FROM PREVIOUS INSPECTION |
|
| 11/23/2009 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO OBTAIN PERMITS FOR ALL NEW WORK 2) CANNOT EXIT TOP END WALL. DO NOT RUN BRANCH CIRCUITS IN BARRIER SECTION 3) NEUTRAL CONDUCTORS TO BE IDENTIFIED ALONG ENTIRE LENGTH 4) EQUIPMENT GROUNDS TO BE SPLICED PROPERLY, USE WIRE NUTS OR CRIMPS 5) PROPERLY INSTALL BONDING JUMPER TO BOND BUSHING 6) THIS PROPERTY ALREADY HAS RECONNECT PERMIT THAT WAS NEVER FINALED. NEED TO COMPLY WITH RECONNECT INSPECTION REQUIREMENTS 7) ONCE PERMIT IS OBTAINED FOR ALL NEW WORK, INSTALL GFI RECEPT AT PANEL. DISCONNECT ALL BRANCH CIRCUITS FOR TEMP CONSTRUCTION POWER |