Permit: T09EL02480

Parcel: 120062200


Addresses:

4123 S 5TH AV

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/10/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST ADDRESSES ON UNITS
2) GROUNDED RECEPTACLES ON UNGROUNDED CIRCUITS
3) KITCHEN RECEPTS TO BE GFCI PROTECTED
4) BASE BOARD HEATER FALLING OFF WALL
5) PROTECT BULB IN CLOSETS
6) BATHROOM RECEPT TO BE GFCI PROTECTED
7) INSTALL SMOKE DETECTORS TO MANUFACTURES INSTRUCTIONS
8) USE APPROVED WIRING METHODS OUTDOORS
9) SECURE RACEWAYS TO STRUCTURE
10) DEVICE IN COMBUSTIBLES-SWITCH 314.20