Permit: T09EL02289

Parcel: 130022170


Addresses:

1812 S 30TH PL

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/20/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
10/15/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WIRING FOR FOUNTAIN NON CODE COMPLIANT. INSTALL PER CODE OR REMOVE
2) HAVE OPEN SPLICES IN CARPORT INSTALL IN JUNCTION BOXES OR REMOVE WIRING. BOXES IN CARPORT TIO BE WEATHER PROOF FOR SWITCH AND HAVE WEATHER PROOF COVER
3) KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED
4) BATHROOM RECEPTACLES TO BE GFI PROTECTED
5) INSTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS
6) INSTALL SMOKE DETECTORS IN REST OF HOME PER INSTRUCTIONS
7) OUTDOOR RECEPTS TO BE GFI PROTECTED
8) NEED PANEL DIRECTORY
9) RECALL WHEN COMPLETE