Permit: T09EL02280

Parcel: 138144520

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T09EL02280

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
10/20/2009 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
1) ITEMS ON LIST OK
10/15/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SMOKE DETECTORS REQUIRED IN BEDROOM AND HALLWAY LEADING TO BEDROOM
2) GFCI RECEPTACLES REQUIRED ABOVE KITCHEN COUNTER
3) RECEPTACLES IN FURNACE ROOM LOOSE, COVER PLATE NOT PROVIDING COMPLETE CLOSURE TO WALL
4) APPLIANCE CORD TO FURNACE LOOSE AT FITTING IN HOUSING. VERIFY CONNECTIONS INSIDE AND TIGHTEN
5) WIRES HANGING OUT OF EXHAUST FAN IN BATH
6) LOAD SIDE CONDUCTORS AT DISCONNECT HAVE CRACKED AND DETERIORATING INSULATION-REPLACE
7) MAKE UNIT LABEL ON DISCONNECT READABLE
8) CORRECT STRANDED GROUND CONNECTION A GROUNDING LUG