Permit: T09EL02276

Parcel: 13219066F


Addresses:

2938 E KENTUCKY ST

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE RELOCATION

Date Description Inspector Results Comments
02/01/2010 ELECTRIC - SERVICE RELOCATION Approved IVRS - Inspection :*
12/18/2009 ELECTRIC - SERVICE RELOCATION Partial Approval IVRS - Inspection :*
12/11/2009 ELECTRIC - SERVICE RELOCATION Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) finish previous items #2,3,5,6,7
A REFEE MAY BE ASSESSED.
12/08/2009 ELECTRIC - SERVICE RELOCATION Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) A PERMANENT METAL ADDRESS LABEL IS NEEDED
2) INSTALL GROUNDING ELECTRODE SYSTEM, GAS AND WATER BONDS
3) VERIFY PERMITS FOR NEW NM CABLES AND WIRING
4) MAINTAIN WORKING CLEARNACE IN FRONT OF SERVICE
5) SUPPORT RISER ABOVE PANEL
6) A LISTED MAST BRACE KIT IS NEEDED
7) ANTI-OXIDE COMPOUND IS NEED FOR ALUMNINUM CONDUCTORS
8) MISSING DEAD FRONT COVER
11/10/2009 ELECTRIC - SERVICE RELOCATION Denied IVRS - Inspection :
There is no access to the site.| 920*
1) GATE LOCKED, NO ACCESS