Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T09EL02274
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/20/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
03/30/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE ALL ITEMS FROM PREVIOUS INSPECTION. NEED TO BE 100 PERCENT COMPLETE 2) NEXT INSPECTION OR WILL NEED TO PAY REINSPECTION FEE |
|
10/14/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL MISSING WALL PLATES 2) BLANK OPEN CEILING BOXES 3) REINSTALL RECEPTACLES HANGING OUT OF WALLS 4) INSTALL SMOKE DETECTORS IN BEDROOMS AND OUTSIDE BEDROOMS 5) HALLWAYS TO HAVE WORKING LIGHT FIXTURES 6) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED 7) BLANK OPEN BREAKER POSITIONS IN PANEL 8) OUTDOOR RECEPTACLES TO BE GFI PROTECTED AND HAVE WORKING WEATHER PROOF COVERS 9) VERIFY GROUNDED RECEPTACLES, HAVE EQUIPMENT GROUND 10) HAVE QUALIFIED ELECTRICAL CONTRACTOR MAKE CORRECTIONS AND CHECK WIRING OF HOME |