Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
Permit Number - T09EL02266
Inspection Description - ELECTRIC - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/19/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MUST HAVE QUALIFIED ELECTRICIAN GO THRU RESIDENCE AND CORRECT ALL CODE VIOLATIONS 2) CORRECTIONS TO NUMEROUS TO ITEMIZE SOME EXAMPLES: A) SERVICE PANEL HAS BREAKER OPENINGS IN DEAD FRONT B) RECEPTACLES AND/OR COVER PLATES IN VARIOUS STATES OF DISREPAIRK BROKEN OR MISSING C) RECEPTACLES IN BATHROOMS, KITCHEN AND EXTERIOR LOCATIONS REQUIRED TO BE GFI PROTECTED D) IMPROPER WIRING METHODS BOTH INSIDE AND OUTSIDE VARIOUS CORDS, DANGLING ROMEX, EXPOSED WIRES AND CONDUITS E) HOT WATER HEATER SHOULD BE HARDWIRED UNLESS PERMITTED BY APPLIANCE LISTING. EXISTING CORD IMPROPERLY INSTALLED 3) OTHER BLDG SAFETY/HABITABILITY CONCERNS: A) POOL BARRIER IN STATE OF DISREPAIR B) EMERGENCY EGRESS NOT POSSIBLE FROM BOARDED UP BEDROOM WINDOW C) ETC... |