Permit: T09EL02247

Parcel: 137031240


Addresses:

5207 S CHAMPION SV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/17/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/13/2009 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) ELECTRICIAN STATES OWNER WAS RESPONSIBLE FOR RECEPTS-FINISH #1 & 3 PREVIOUS INSPECTION 10/07/09
11/12/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) NEED A CONNECTOR FOR HOOD-WHERE DOES NEW NM CABLE CONNECT TO
2) USE APPROVED HARDWIRE WITH DEVICES
3) HOW WAS KITCHE WIRED ?
4) PANEL LABELING TO BE AS PER 408.4
5) FINISH 1, 3, 6, 11 & 14
10/07/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUNDED RECEPTACLES ON AN UNDERGROUNDED SYSTEM
2) BROKEN RECEPTACLES
3) BOXES MORE THAN 1/4" IN NON COMBUSTIBLES-1/2" PLUS
4) MISSING HOOD
5) NEED LIGHTING OUTLET IN BEDROOM
6) INSTALL SMOKE DETECTORS TO MANUFACTURERS INSTRUCTIONS
7) NO KITCHEN RECEPTACLES INSTALLED, ALSO MUST BE GFCI
8) BATHROOM RECEPTACLE TO BE GFCI
9) COMPLETELY IDENTIFY UNGROUNDED CONDUCTOR IN PANEL
10) ONLY ONE CONDUCTOR PER LUG TERMINATION
11) WHERE IS CIRCUIT NEUTRAL FOR COOLER
12) NEED PERMANENT METAL ADDRESS LABEL ON PANEL
13) FIXTURE NEEDS A JUNCTION BOX
14) PLEASE HAVE QUALIFIED ELECTRICIAN PERFORM WORK