Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/17/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 11/13/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) ELECTRICIAN STATES OWNER WAS RESPONSIBLE FOR RECEPTS-FINISH #1 & 3 PREVIOUS INSPECTION 10/07/09 |
|
| 11/12/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) NEED A CONNECTOR FOR HOOD-WHERE DOES NEW NM CABLE CONNECT TO 2) USE APPROVED HARDWIRE WITH DEVICES 3) HOW WAS KITCHE WIRED ? 4) PANEL LABELING TO BE AS PER 408.4 5) FINISH 1, 3, 6, 11 & 14 |
|
| 10/07/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUNDED RECEPTACLES ON AN UNDERGROUNDED SYSTEM 2) BROKEN RECEPTACLES 3) BOXES MORE THAN 1/4" IN NON COMBUSTIBLES-1/2" PLUS 4) MISSING HOOD 5) NEED LIGHTING OUTLET IN BEDROOM 6) INSTALL SMOKE DETECTORS TO MANUFACTURERS INSTRUCTIONS 7) NO KITCHEN RECEPTACLES INSTALLED, ALSO MUST BE GFCI 8) BATHROOM RECEPTACLE TO BE GFCI 9) COMPLETELY IDENTIFY UNGROUNDED CONDUCTOR IN PANEL 10) ONLY ONE CONDUCTOR PER LUG TERMINATION 11) WHERE IS CIRCUIT NEUTRAL FOR COOLER 12) NEED PERMANENT METAL ADDRESS LABEL ON PANEL 13) FIXTURE NEEDS A JUNCTION BOX 14) PLEASE HAVE QUALIFIED ELECTRICIAN PERFORM WORK |