Permit: T09EL02217

Parcel: 135081520


Addresses:

7310 E 28TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/04/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
1) NO NEED TO SEND CLEARANCE BECAUSE OF UPGRADE PERMIT ARLEADY HAD CLEARANCE SENT
10/07/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED
2) CLOSE OPEN JUNCTION BOX AT DRYER
3) REMOVE NON-CODE COMPLIANT TAPS FROM DRYER RECEPTACLE
4) REMOVE SWAGGED CEILING FAN, NOT PROPERLY WIRED OR GROUNDED
5) INSTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS
6) REMOVE NON CODE COMPLIANT TOP FROM OUTSIDE LIGHT JUNCTION BOX AND INSTALL OUTSIDE LIGHT
7) NEED PANEL SCHEDULE
8) REMOVE FLOOD LIGHTS AND ASSOCIATED WIRING BACKYARD. NON CODE COMPLIANT
9) VERIFY PERMITS FOR NEW WATER HEATER, FURNACE AND A/C UNIT
10) BATHROOM RECEPTACLES TO BE GFI PROTECTED
11) INSTALL MISSING WALL PLATES
12) HAVE GROUNDED RECEPTACLES ON UNDERGROUND SYSTEM
13) HAVE QUALIFIED ELECTRICAL CONTRACTOR MAKE CORRECTIONS
10/05/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
1) HOUSE LOCKED, NO ACCESS
2) PLEASE PROVIDE ACCESS TO INTERIOR