Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/04/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* 1) NO NEED TO SEND CLEARANCE BECAUSE OF UPGRADE PERMIT ARLEADY HAD CLEARANCE SENT |
|
| 10/07/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED 2) CLOSE OPEN JUNCTION BOX AT DRYER 3) REMOVE NON-CODE COMPLIANT TAPS FROM DRYER RECEPTACLE 4) REMOVE SWAGGED CEILING FAN, NOT PROPERLY WIRED OR GROUNDED 5) INSTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS 6) REMOVE NON CODE COMPLIANT TOP FROM OUTSIDE LIGHT JUNCTION BOX AND INSTALL OUTSIDE LIGHT 7) NEED PANEL SCHEDULE 8) REMOVE FLOOD LIGHTS AND ASSOCIATED WIRING BACKYARD. NON CODE COMPLIANT 9) VERIFY PERMITS FOR NEW WATER HEATER, FURNACE AND A/C UNIT 10) BATHROOM RECEPTACLES TO BE GFI PROTECTED 11) INSTALL MISSING WALL PLATES 12) HAVE GROUNDED RECEPTACLES ON UNDERGROUND SYSTEM 13) HAVE QUALIFIED ELECTRICAL CONTRACTOR MAKE CORRECTIONS |
|
| 10/05/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* 1) HOUSE LOCKED, NO ACCESS 2) PLEASE PROVIDE ACCESS TO INTERIOR |