Permit: T09EL02014

Parcel: 111041740


Addresses:

3526 E KLEINDALE RD

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
09/08/2009 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
09/03/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SERVICE PANEL COMING OFF WALL NEEDS TO BE REATTACHED - DO NOT USE PLASTIC ANCHORS
2. ATTACH MAST TO BUILDING STRUCTURE WITH 1/4" STAINLESS HARDWARE
3. REMOVE NON-CODE COMPLIANT WIRING AT FRONT PORCH ALL OUTDOOR WIRING TO BE WEATHERPROOF -
OUTDOOR 15 & 20 amp - 120 V RECEPTACLES TO BE GFI PROTECTED.
4. SMOKE DETECTORS TO BE 36" FROM VENTS
5. INSTALL SMOKE DETECTORS IN BEDROOMS AND HALL OUTSIDE BEDROOMS
6. INCANDESCENT CLOSET LIGHTS TO BE 100% ENCLOSED
7. HAVE 2-WIRE UNGROUNDED SYSTEM INSTALL 2-PRONG RECEPTACLES OR GROUNDING TYPE RECEPTACLES TO BE GFI PROTECTED
8. INSTALL MISSING WALL PLATES