Permit: T09EL01991

Parcel: 137281350


Addresses:

932 W WEDWICK ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/10/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
12/02/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) WHERE IS GROUNDING ELECTRODE SYSTEM
2) FINISH #1,2,3 & 5 PREVIOUS INSPECTION
10/23/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
COMPLETE ALL ITEMS FROM 9-1-09 INSPECTION.
INSPECTIONS WITH NO PROGRESS WILL RESULT IN A REINSPECTION FEE.
09/01/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FRONT LIGHT AND BOX NEEDED
2) SECURE NM CABLE FOR HOOD AND USE A CONNECTOR AT HOOD
3) MISSING LIGHT FIXTURES
4) NEED SMOKE DETECTORS BEDROOMS
5) NEED PERMANENT METAL ADDRESS LABEL AT METER
6) FILL UNUSED OPENINGS
7) BREAKERS TO BE LISTED FOR USE BY MANUFACTURER
8) ONLY ONE GROUNDED CONDUCTOR PER TERMINAL LUG AND CONNECT ALL
9) MAIN BREAKER TO USE MANUFACTURERS HOLDOWN
10) LABEL BREAKERS
11) VERIFY COOLER WIRING TO CODE
12) RECONNECT WATER BOND