Permit: T09EL01959

Parcel: 12617238D

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/25/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/17/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/27/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLANK OPEN BREAKER POSITIONS IN PANEL
2) INSTALL BREAKERS LISTED FOR USE IN PANEL
3) NEED PANEL DIRECTORY
4) STRAP ALL RACEWAYS ON OUTSIDE OF HOUSE PER NEC. SECURE BOXES
5) ONE NEUTRAL PER TERMINAL IN PANEL
6) MISSING RECEPTACLE WALL PLATE
7) INSTALL BATTERYS IN SMOKE DETECTORS
8) INCANDECENT CLOSET LIGHT TO BE 100 PERCENT ENCLOSED
9) INSTALL SMOKE DETECTORS IN ALL BEDROOMS AND OUTSIDE OF BEDROOMS