Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* 1) LAST INSPECTION ITEM CORRECTED |
|
| 08/28/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED SPRING RELIEF FOR CORD 2) NEED PANEL SCHEDULE 3) CALL BACK FOR FINAL |
|
| 08/27/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SOUTH OUTSIDE WALL NEEDS WEATHER PROOF COVER FOR OUTLET 2) NEED COVER PLATE AND ARC SHIELDS 3) NEED GFI IN BATHROOM & KITCHEN 4) NEED PANEL SCHEDULE 5) NEED CORD RELIEF FOR DROP CORD 6) NEED WEATHER PROOF COVER FOR OUTLET AT SERVICE 7) NEED GAS BOND |