Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09EL01927

Parcel: 117082230


Addresses:

902 S 6TH AV


Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Permit Number - T09EL01927

Inspection Description - ELECTRIC - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
08/21/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST ADDRESS ON BLDG
2) GROUNDED RECEPTACLES ON AN UNGROUNDED SYSTEM
3) OUTDOOR LIGHT TO BE FOR WET LOCATION
4) NEED WORKING CLEARANCE IN FRONT OF SERVICE
5) LABEL SERVICE
6) FILL UNUSED OPENINGS IN PANEL
7) LABEL CIRCUITS
8) AUTO SHOP EQUIPMENT ON SITE HAS NO RECEPTACLES OR POWER OUTLETS FOR USE
9) NO PROPER WIRING ON ROOF FOR HEATING OR COOLING
10) NO HEATING OR COOLING UNIT PRESENT