Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
Permit Number - T09EL01927
Inspection Description - ELECTRIC - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/21/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST ADDRESS ON BLDG 2) GROUNDED RECEPTACLES ON AN UNGROUNDED SYSTEM 3) OUTDOOR LIGHT TO BE FOR WET LOCATION 4) NEED WORKING CLEARANCE IN FRONT OF SERVICE 5) LABEL SERVICE 6) FILL UNUSED OPENINGS IN PANEL 7) LABEL CIRCUITS 8) AUTO SHOP EQUIPMENT ON SITE HAS NO RECEPTACLES OR POWER OUTLETS FOR USE 9) NO PROPER WIRING ON ROOF FOR HEATING OR COOLING 10) NO HEATING OR COOLING UNIT PRESENT |