Permit: T09EL01879

Parcel: 133310560


Addresses:

8949 E COOPER ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/03/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
08/19/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPLACE OUTDOOR LIGHT FIXTURE AT FRONT DOOR. NEED TO BE WIRED PER CODE AND BE A LISTED FIXTURE
2) OUTDOOR RECEPTACLES TO BE GFI PROTECTED
3) NEED PANEL DIRECTORY
4) SEAL OPEN KNOCKOUTS
5) INSTALL MAIN BONDING JUMPER IN PANEL
6) KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED
7) INSTALL SMOKE DETECTORS IN BEDOOMS. INSTALL NEW SMOKE DETECTOR IN HALLWAY
8) INCANDECENT CLOSET LIGHTS TO BE 100 PERCENT ENCLOSED
9) BATHROOM RECEPTACLES TO BE GFI PROTECTED INCLUDING RECEPT IN LIGHT FIXTURE
10) HAVE #10 AWG WIRES IN PANEL ON 40 AMP BREAKER ?
11) HAVE QUALIFIED ELECTRICAL CONTRACTOR MAKE CORRECTIONS AND THEN RECALL