Permit: T09EL01734

Parcel: 126134340


Addresses:

4543 E DOUGLAS ST

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/05/2009 ELECTRIC - FINAL Denied
07/28/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL GFI PROTECTION FOR KITCHEN COUNTER TOP RECEPTACLES
2) EXHAUST HOOD NEEDS EQUIPMENT GROUND. CANNOT BE CORD CONNECTED. NEEDS TO BE HARDWIRED
3) SMOKE DETECTORS IN BEDROOMS TO BE MINIMUM 36" FROM VENT
4) BATHROOM RECEPTACLES TO BE GFI PROTECTED
5) OUTDOOR RECEPTACLES TO BE GFI PROTECTED AND HAVE WEATHER PROOF COVER
6) HAVE 2 WIRE UNGROUNDED SYSTEM THRU OUT HOUSE, INSTALL 2 PRONG RECEPTACLES OR GFI PROTECTION ON RECEPTACLES
7) NEED TO VERIFY PERMITS FOR NEW SERVICE PANELS AND SUB PANELS