Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* 1) CALLED INTO OFFICE FOR PM CLEARANCE |
|
| 08/04/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) ONLY ONE CONDUCTOR TO A TERMANIAL LUG 2) A CONNECTOR IS NEEDED FOR NEW NM CABLE AT SUB PANEL 3) SEPERATE GROUNDS AND NEUTRALS AT SUB PANEL 250.24 4) GROUNDED RECEPTACLES ON UNDERGROUND SYSTEM |
|
| 07/31/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) FILL UNUSED OPENING IN SUB PANEL-COVER BY PANEL 2) PLEASE FINISH ITEM 2,5,7,9,10 AND 11 |
|
| 07/28/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING FRONT OUTSIDE LIGHT 2) GROUNDED RECEPTACLES ON UNGROUNDED CIRCUITS 3) MISSING DEVICES 4) BACK PORCH LIGHT IMPROPERLY INSTALLED 5) SUPPORT CONDUITS ON SIDE OF PANEL 6) MISSING SUB PANEL COVER 7) EXPOSED NM CABLE ON BACK PORCH 8) CANNOT PAINT SMOKE DETECTOR 9) CLEAN EXCESS PAINT AND FOREIGN MATERIAL FROM DEVICES 10) BROKEN BEDROOM LIGHTS 11) NEED GFCI RECEPTACLES FOR BATHROOMS |