Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2009 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/27/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 08/13/2009 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PREVIOUS INSPECTION ITEMS CORRECTED 2) FURNACE NEEDS TO BE REPLACED BY DIRECTION OF SOUTH WEST GAS 3) NEED TO PULL PERMIT, ONCE PERMIT IS PULLED POWER CAN BE RELEASED 4) HOUSE IS NOT HABITABLE WITHOUT HEAT |
|
| 07/17/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OUTDOOR RECEPTACLES TO BE GFI PROTECTED 2) BOXES UNDER EVE MISSING KNOCKOUTS 3) PROPERLY INSTALL/WIRE OUTDOOR LIGHTS, CANNOT USE ROMEX WITH CORD CAP 4) PROPERLY INSTALL WEATHER PROOF COVERS ON RECEPTACLE BOXES 5) LABEL CIRCUITS AT PANEL 6) OUTDOOR ? LIGHT TO BE PROPERLY INSTALLED 7) ALL KITCHEN COUNTER RECEPTACLE TO BE GFI PROTECTED 8) HAVE 3 PRONG GROUNDED RECEPTACLES ON 2 WIRE UNGROUNDED SYSTEM 9) REPLACE BROKEN RECEPTACLE PLATES AND MISSING PLATES 10) PROPERLY INSTALL RECEPTACLE FOR DISHWASHER 11) PROPERLY WIRE CEILING FIXTURES IN BEDROOMS AND CEILING FANS 12) INSTALL SMOKE DETECTORS IN BEDROOMS AND HALLWAY PER INSTRUCTIONS 13) REPLACE CORD TO FURNACE 14) PROPERLY INSTALL WIRING IN CARPORT 15) VERIFY PERMIT FOR NEW WATER HEATER. NOT INSTALLED PER CODE 16) HAVE QUALIFIED ELECTRICAL CONTRACTOR MAKE REPAIRS/FIXES |