Permit: T09EL01652

Parcel: 136191800


Addresses:

3237 S TAHOE DR

Inspection Status: Not ready for Inspection

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/27/2009 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
08/27/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
08/13/2009 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) PREVIOUS INSPECTION ITEMS CORRECTED
2) FURNACE NEEDS TO BE REPLACED BY DIRECTION OF SOUTH WEST GAS
3) NEED TO PULL PERMIT, ONCE PERMIT IS PULLED POWER CAN BE RELEASED
4) HOUSE IS NOT HABITABLE WITHOUT HEAT
07/17/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OUTDOOR RECEPTACLES TO BE GFI PROTECTED
2) BOXES UNDER EVE MISSING KNOCKOUTS
3) PROPERLY INSTALL/WIRE OUTDOOR LIGHTS, CANNOT USE ROMEX WITH CORD CAP
4) PROPERLY INSTALL WEATHER PROOF COVERS ON RECEPTACLE BOXES
5) LABEL CIRCUITS AT PANEL
6) OUTDOOR ? LIGHT TO BE PROPERLY INSTALLED
7) ALL KITCHEN COUNTER RECEPTACLE TO BE GFI PROTECTED
8) HAVE 3 PRONG GROUNDED RECEPTACLES ON 2 WIRE UNGROUNDED SYSTEM
9) REPLACE BROKEN RECEPTACLE PLATES AND MISSING PLATES
10) PROPERLY INSTALL RECEPTACLE FOR DISHWASHER
11) PROPERLY WIRE CEILING FIXTURES IN BEDROOMS AND CEILING FANS
12) INSTALL SMOKE DETECTORS IN BEDROOMS AND HALLWAY PER INSTRUCTIONS
13) REPLACE CORD TO FURNACE
14) PROPERLY INSTALL WIRING IN CARPORT
15) VERIFY PERMIT FOR NEW WATER HEATER. NOT INSTALLED PER CODE
16) HAVE QUALIFIED ELECTRICAL CONTRACTOR MAKE REPAIRS/FIXES