Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09EL01616

Parcel: 133360840


Addresses:

302 N BANFF AV

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
07/30/2009 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
07/27/2009 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
There is no access to the site.| 920*
07/22/2009 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*
1) OK GROUND RODS
2) OK GAS AND WATER BOND
3) NEED PANEL DIRECTORY
4) SEAL OPENING AT BACK OF PANEL WHERE WIRES ENTER WITH NON-COMBUSTIBLE MATERIAL
5) RECALL WHEN READY