Permit: T09EL01609

Parcel: 138180980

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
02/09/2010 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
01/14/2010 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*
1) CLEAN SURFACE UNDER GROUND LUG 250.12
2) INSULATE NEUTRAL CONDUCTOR IN JUNCTION BOX
01/06/2010 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*
01/05/2010 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WORKING CLEARANCES 110.26
2) PLEASE VERIFY WHO IS QUALIFIED ELECTRICIAN
3) A REFEE MAY BE ASSESSED
12/29/2009 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) A LISTED MAST BRACE IS NEEDED AND SECURED TO A JOIST
2) FINISH #1 (110.26) AND #2
12/23/2009 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) MAINTAIN WORKING CLEARANCES 110.26
2) RISER HARDWARE TO BE 1/4" MIN
3) HIGHEST AVAILABLE BREAKER NOT TO BE OVER 6' 7"
4) FILL UNUSED PORTION OF OPENING WITH APPROVED FITTING
5) SECURE BONDING CONDUCTOR AND BURY
6) DRIVE GROUND RODS FLUSH
7) PLEASE IDENTIFY GROUNDED CONDUCTOR CLOSER TO WEATHER HEAD
8) VERIFY ROOF JACK INSTALLATION
9) MAINTAIN CLEARANCE ACROSS ROOF