Permit: T09EL01543

Parcel: 133291180

Inspection Status: Cancelled

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/16/2009 ELECTRIC - FINAL Cancelled IVRS - RI canceled
09/16/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
08/28/2009 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
06/29/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL WIRES BELOW 8' AFF IN STORE ROOM MUST BE PROTECTED
2) REPAIR AND PROPERLY SUPPORT CONDUIT TO A/C UNIT
3) KITCHEN COUNTER RECEPTACLES NEED TO BE GFI PROTECTED
4) DISCONNECT RECEPTACLES IN BATH LIGHTS OR GFI PROTECT
5) INSTALL SMOKE DETECTORS ALL BEDROOMS AND HALLWAYS AT LEAST 3' FROM REGISTERS AND BETWEEN 6" AND 12" OF CEILING IF WALL MOUNTED