Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T09EL01500
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/12/2009 | ELECTRIC - FINAL | Approved | PER FINALED T09CM01958 | |
| 07/08/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL KNOCKOUTS PANEL AND SUB PANEL 2) 50 AMP WHITE HOT LEADS MUST BE BLACK OR RED 3) SEAL OPENINGS IN DEAD FRONT 4) NOTES 1,2,4 & 5 FROM PREVIOUS 5) REAR ATTACHED STORAGE CONVERTED TO BEDROOM, NO HEAT OR COOLING 6) REAR PORCHES CONVERTED TO HABITABLE SPACE CODE COMPLIANCE PERMIT REQUIRED NEW OWNERS. SUBMIT SITE PLAN AND FLOOR PLAN 7) UPGRADE MAYBE REQUIRED 8) REMOVE ALL ELECTRICAL FROM DETACHED STORAGE OR PERMIT |
|
| 06/23/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST HOUSE NUMBERS 2) GFCI PROTECT EXTERIOR OUTLETS 3) PROVIDE ACCESS TO PANEL 4) PROVIDE PROOF OF PERMIT ELECTRICAL IN STORAGE OR REMOVE 5) PROVIDE PROOF OF PERMIT ALL ADDITIONS TO PROPERTY 6) OMIT HAZARDOUS ELECTRICAL NOT TO CODE LAUNDRY 220 7) OMIT EXPOSED ROMEX AND ZIP CORD LAUNDRY ROOM 8) GFCI PROTECT BATH OUTLET 9) SMOKE ALARM BEDROOMS 10) BEDROOM BARS MUST OPERATE PROPERLY FOR EGRESS WITHOUT SEPERATE TOOLS 11) MISSING COVER PLATES THROUGHOUT 12) COMPLETE DISHWASHER CONNECTION 13) EXTERIOR ROMEX REAR PORCH NOT TO CODE |
|
| 06/22/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS TO INTERIOR OF UNIT, RECALL 11:30 AM |