Permit: T09EL01500

Parcel: 138060780

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T09EL01500

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/12/2009 ELECTRIC - FINAL Approved PER FINALED T09CM01958
07/08/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL KNOCKOUTS PANEL AND SUB PANEL
2) 50 AMP WHITE HOT LEADS MUST BE BLACK OR RED
3) SEAL OPENINGS IN DEAD FRONT
4) NOTES 1,2,4 & 5 FROM PREVIOUS
5) REAR ATTACHED STORAGE CONVERTED TO BEDROOM, NO HEAT OR COOLING
6) REAR PORCHES CONVERTED TO HABITABLE SPACE CODE COMPLIANCE PERMIT REQUIRED NEW OWNERS. SUBMIT SITE PLAN AND FLOOR PLAN
7) UPGRADE MAYBE REQUIRED
8) REMOVE ALL ELECTRICAL FROM DETACHED STORAGE OR PERMIT
06/23/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST HOUSE NUMBERS
2) GFCI PROTECT EXTERIOR OUTLETS
3) PROVIDE ACCESS TO PANEL
4) PROVIDE PROOF OF PERMIT ELECTRICAL IN STORAGE OR REMOVE
5) PROVIDE PROOF OF PERMIT ALL ADDITIONS TO PROPERTY
6) OMIT HAZARDOUS ELECTRICAL NOT TO CODE LAUNDRY 220
7) OMIT EXPOSED ROMEX AND ZIP CORD LAUNDRY ROOM
8) GFCI PROTECT BATH OUTLET
9) SMOKE ALARM BEDROOMS
10) BEDROOM BARS MUST OPERATE PROPERLY FOR EGRESS WITHOUT SEPERATE TOOLS
11) MISSING COVER PLATES THROUGHOUT
12) COMPLETE DISHWASHER CONNECTION
13) EXTERIOR ROMEX REAR PORCH NOT TO CODE
06/22/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS TO INTERIOR OF UNIT, RECALL 11:30 AM