Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2009 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* 1) #1,4 AND 5 NOT DONE FROM 6/15/09 INSPECTION 2) RECALL WHEN CORRECTIONS ARE COMPLETE AND POWER HAS BEEN RESTORED, FOR FINAL INSPECTION |
|
| 06/15/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SCREW WATER HEATER VENT PIPE TOGETHER MINIMUM 3 SCREWS AT EACH SEAM 2) KITCHEN COUNTER RECEPTACLE NEEDS GFI PROTECTION 3) BATH RECEPTACLE NEEDS GFI PROTECTION 4) SMOKE DETECTOR REQUIRED IN BEDROOM AT LEAST 3' FROM COOLER REGISTER AND BETWEEN 6" AND 12" OF CEILING IF WALL MOUNTED 5) NEED ADDRESS ON MAIN DISCONNECT SWITCH AT NORTH END OF BLDG |