Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T09EL01380
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2009 | ELECTRIC - RECONNECT | Approved | ||
06/03/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER PRESSURE RELIEF LINE TO GROUDN 6"-24" MUST BE COPPER 3/4" OR CVPC 2) 2 WIRE OUTLETS MIXED WITH 2 WIRE WITH GROUND THROUGHOUT 3) SMOKE ALARM BEDROOM 4) MISSING COVER PLATES 5) GFCI PROTECT BATH FIXTURE OR REPLACE WITH ONE W/O OUTLET 6) GFCI PROTECT KITCHEN COUNTER OUTLET |