Permit: T09EL01203

Parcel: 113030430


Addresses:

765 E PASTIME RD


Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T09EL01203

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
05/29/2009 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
05/28/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BUBBLE COVER REQUIRED AT COOLER OUTLET
2) REPLACE ALL GROUND OUTLETS WITH 2-PRONG OUTLETS WHERE GROUND IS NOT AVAILABLE
3) ALL KITCHEN OUTLETS SHALL BE GFI
05/20/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) IDENTIFY ELECTRIC METER AND DISCONNECT WITH PERMANENT ADDRESS LABEL
2) 1" CLEARANCE REQUIRED AT WATER HEATER "B" VENT FROM COMBUSTIBLE AND CONNECT TO DIVERTER
3) EXTEND PTR LINE 6" MIN 24" MAX FROM FLOOR
4) GFI PROTECTED OUTLETS REQUIRED IN KITCHEN AND BATHROOM
5) SEAL TOILET AT FLOOR WITH CAULKING
6) REDO COOLER BOX, PROVIDE FUSE PROTECTION
7) REMOVE PANEL COVER FROM BREAKER SUB PANEL
8) SMOKE ALARM MISSING IN BEDROOM