Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/29/2009 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 05/28/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BUBBLE COVER REQUIRED AT COOLER OUTLET 2) REPLACE ALL GROUND OUTLETS WITH 2-PRONG OUTLETS WHERE GROUND IS NOT AVAILABLE 3) ALL KITCHEN OUTLETS SHALL BE GFI |
|
| 05/20/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) IDENTIFY ELECTRIC METER AND DISCONNECT WITH PERMANENT ADDRESS LABEL 2) 1" CLEARANCE REQUIRED AT WATER HEATER "B" VENT FROM COMBUSTIBLE AND CONNECT TO DIVERTER 3) EXTEND PTR LINE 6" MIN 24" MAX FROM FLOOR 4) GFI PROTECTED OUTLETS REQUIRED IN KITCHEN AND BATHROOM 5) SEAL TOILET AT FLOOR WITH CAULKING 6) REDO COOLER BOX, PROVIDE FUSE PROTECTION 7) REMOVE PANEL COVER FROM BREAKER SUB PANEL 8) SMOKE ALARM MISSING IN BEDROOM |