Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/19/2009 | ELECTRIC - RECONNECT | Approved | ||
| 05/19/2009 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 05/12/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE PROOF OF PERMIT ADDITION ON SOUTH PROPERTY LINE 2) SECURE CONDUIT TO BLDG AT SERVICE 3) SEAL JUNCTION BOX KNOCKOUTS 4) PROVIDE PROPER CONNECTOR FLEX TO JUNCTION BOX 5) SWITCHED LIGHTS ALL EXIT DOORS 6) NEW WATER HEATER BEING INSTALLED, REQUIRES PERMIT AND A/C UNIT ON ROOF TOP 7) GFCI PROTECT KITCHEN COUNTER OUTLET 8) SMOKE ALARMS IN BEDROOMS AND ADJACENT HALLWAY 9) OMIT EXISTING LIGHT IN ADDITION CLOSET 10) CODE COMPLIANT PERMIT RECOMMENDED 11) EXPLAINED TO OWNER ZONING MAY NOT APPROVE ADDITION ON SOUTH PROPERTY LINE |