Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/22/2009 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 07/17/2009 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ON EXISTING 3 WIRE RANGE RECEPTACLE. CAN USE NEUTRAL TO GROUND RANGE BUT CANNOT USE EQUIPMENT GROUND AS NEUTRAL 2) ON EXISTING SUB PANEL CABLE, HAVE INSULATION COMING OFF OF PHASE CONDUCTOR AND COPPER & ALUMINUM CANNOT BE SPLICED TOGETHER |
|
| 07/10/2009 | ELECTRIC - SERVICE UPGRADE | Partial Approval | IVRS - Inspection :* 1) RECALL AFTER SWING OVER COMPLETE 2) POOL BEING RELOCATED TO NET PROPER CLEARANCE |
|
| 06/17/2009 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* OVERHEAD SERVICE CONDUCTORS TO MEET CLEARANCE REQUIREMENTS OF NEC 680.8 |