Permit: T09EL00738

Parcel: 123141020


Addresses:

845 E LINDEN ST


Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T09EL00738

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
05/21/2009 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
04/07/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SMOKIES IN ALL BEDROOMS
2) GFI-PROTECTED RECEPTACLES AT KITCHEN COUNTER AND BATHROOM
3) BLANK OR COMPLETE ALL RECEPTACLES AND SWITCHES
4) WATER HEATER NEEDS TPR LINE
5) WILL NEED 2 GROUND RODS-6' APART AT SERVICE PANEL
6) NEED TO INSTALL DOOR OR WINDOW IN BACK BEDROOM
7) WILL NEED TO GET A SERVICE UPGRADE INSPECTION. FEEDERS COMING INTO INSULATION, NEED TO COME INTO SERVICE HEAD, WILL NEED TO RAISE RISER