Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2009 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 06/05/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NOTE 10 FROM PREVIOUS INSPECTION BARS ON BEDROOM WINDOWS MUST OPERATE PROPERLY FOR EMERGENCY, EGRESS WITHOUT USE OF SPECIAL TOOLS. 2. NOTE 12 FROM PREVIOUS INSPECTION 3. NOTE 15 FROM PREVIOUS/PROVIDE COMBUSTION RELIEF TO EXTERIOR 100 CU 4. GFCI PROTECT OUTLET @ LAUNDRY WASH BASIN |
|
| 04/24/2009 | ELECTRIC - RECONNECT | Denied | 1) EXPOSED WIRING EXTERIOR N.E. CORNER 2) GFCI PROTECT PORCH OUTLET REAR PROTECT ROMEX FROM PHYSICAL DAMAGE OR OMIT 3) NEW PANEL BOX INSTALLED LACKS REQUIRED DISCONNECT 4) PANEL NOT GROUNDED, GROUND ROD SYSTEM REQUIRED. SECURE PANEL PROPERLY TO BLDG 5) PER TEP SPECS REPLACE RISER WITH 2" MINIMUM 6) 40 AMP WHITE LEAD MUST BE RED OR BLACK (TYPE) 7) LABEL ALL CIRCUITS 8) PROVIDE PROOF OF PERMIT CARPORT ENCLOSURE 9) PROVIDE PROOF OF PERMIT NEW A/C ROOF TOP AND DUCT WORK THROUGHOUT 10) AT LEAST ONE WINDOW BAR IN EACH BEDROOM MUST OPERATE PROPERLY WITHOUT SPECIAL TOOLS FOR EMERGENCY EGRESS 11) EXPOSE WIRING OLD COOLER SWITCH 12) PROTECT ALL ROMEX STORAGE FROM PHYSICAL DAMAGE 13) EXTEND WATER HEATER PRESSURE RELIEF TO EXTERIOR/PROVIDE COMBUSTION RELIEF 14) ALL NEW OUTLETS MUST TEST FOR GROUND |