Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/23/2009 | ELECTRIC - FINAL | Denied | 1) LABEL CIRCUITS 2) COMPLETE REMOVAL PER PREVIOUS NOTE #5 |
|
| 04/06/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GFCI PROTECT KITCHEN COUNTER OUTLETS 2) HAZARDOUS ELECTRIC CONNECTION DISPOSAL 3) SMOKE ALARMS ALL BEDROOMS AND HALLWAY 4) GFCI PROTECT BATH OUTLETS 5) HAZARDOUS ELECTRIC TO ROOF TOP 30 AMP CIRCUIT. PROVIDE WEATHERED FITTINGS AT CONDUIT 6) PANEL MISSING DEAD FRONT 7) REPLACE FAULTY 30 AMP BREAKER 8) REAR LIGHT SWITCH PAINTED IN CLOSED POSITION 9) EXPOSED WIRING THROUGHOUT SWITCHES AND FIXTURES 10) REMOVE ALL EXTENSION CORDS FROM NEIGHBOR 11) PROVIDE ACCESS TO STORAGE |