Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T09EL00706
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/20/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 04/06/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALL MISSING WALL PLATES 2. PROPERLY WIRE FLUORESCENT FIXTURE OR REMOVE 3. ALL WIRING TO TERMINATE IN JUNCTION BOXES 4. CLOSE OPEN KNOCKOUTS IN LIGHT FIXTURES 5. HAVE WIRES HANGING REAR OF UNIT TO BE REMOVED OR INSTALLED IN BOXES AND PROPERLY STRAPPED 6. CLOSE OPEN JUNCTION BOXES 7. BLANK OPEN JUNCTION BOX OUTSIDE REAR OF UNIT 8. GROUNDING ELECTRODE CONDUCTOR CUT AND MISSING FROM SERVICE. BOND GAS AND WATER PIPING TO SERVICE 9. INSTALL WEATHERPROOF COVERS ON RECEPTACLES OUTSIDE REAR OR REMOVE 10. NEED LB COVER AND BLANK OPENINGS REAR OF UNIT OUTSIDE 11. RECALL WHEN READY |