Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 07/31/2009 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED OVER PHONE (272-6135), EXPLAINED AGAIN 3 CHOICES |
|
| 07/29/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ANSWER AT FRONT DOOR 12PM COMPLY WITH PREVIOUS INSPECTIONS OWNER HAS 3 CHOICES 1. RETURN DWELLING TO ITS ORIGINAL STATE PRIOR TO WORK W/O PERMITS 2. OBTAIN CODE COMPLAINCE PERMIT AND COMPLETE ALL INSPECTION AND BRING DWELLING UP TO CODE 3. OBTAIN APPROVED APPEAL FROM BUILDING OFFICIAL FOR WORK TO BE DONE WORK PERFORMED TO DWELLING CAUSES AN UNSAFE CONDITION. TO INCLUDE FIRE SEPERATION AND SAFE ? TO A PUBLIC WAY. NO FURTHER INSPECTIONS TO BE DONE ON THIS PROPERTY UNTIL 1 OF THE ABOVE HAVE BEEN ADDRESSED |
|
| 07/28/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REFER TO DNR |
|
| 07/27/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ANSWER FRONT DOOR 10:30 AM 2) REFEE WILL APPLY NEXT DENIAL |
|
| 07/24/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH PREVIOUS |
|
| 07/22/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST HOUSE NUMBERS VISIBLE FROM STREET 2) NO ANSWER FRONT DOOR 10:00 AM |
|
| 04/06/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTES 10 AND 7 FROM PREVIOUS 2) ATRIUM ENCLOSED DOES NOT ALLOW SAFE EGRESS TO PUBLIC WAY BEDROOM WINDOW COVERED TO EXTERIOR 3) RECORD ROOM MAY NOT BE USED AS A BEDROOM WITH CODE COMPLIANCE PERMIT OR PROVIDE APPEAL APPROVED BY BLDG OFFICIAL |
|
| 04/03/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WIRING IN CARPORT NOT TO CODE OMIT OR INSTALL TO CODE WITH PERMIT 2) PROVIDE ACCESS TO STORAGE 3) HAZARDOUS WIRING 220 DRYER OMIT OR PERMIT 4) GFCI PROTECT KITCHEN OUTLETS 5) DBL LUGGED BREAKERS IN PANEL ADDED 6) PANEL NOT GROUNDED 7) PROVIDE SWITCHED LIGHT REAR EXIT DOOR 8) GFCI PROTECT BATH OUTLETS 9) SMOKE ALARM ALL BEDROOMS AND HALLWAYS 10) BEDROOMS DO NOT HAVE SAFE EGRESS TO PUBLIC WAY 11) ADDED OUTLETS IN STORAGE NOT TO CODE |
|
| 04/02/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ANSWER FRONT DOOR 10:05 AM 2) PROVIDE ACCESS |