Permit: T09EL00694

Parcel: 122163250


Addresses:

3550 E TEARNEY DR


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T09EL00694

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/30/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/20/2009 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) FEEDER FROM (NEW SERVICE) TO SUB PANEL REQUIRES A GRD. (GREEN CODED) ALL THE WAY FROM SERVICE TO SUB PANEL
2) SUB PANEL TO HAVE A ISOLATE NEUTRAL BAR AND GROUND BAR ATTACHED TO THE SUB PANEL CABINET
3) GROUND TO RUN IN SAME RACEWAY
4) J-BOX IN GARAGE TO SMALL
11/03/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*