Permit: T09EL00669

Parcel: 138231730


Addresses:

702 W COVENTRY DR

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/28/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST HOUSE NUMBERS VISIBLE FROM STREET
2) INSTALL T-CAP WATER HEATER FLUE
3) EXTEND RELIEF LINE 6"-24" FROM GROUND 3/4" COPPER
06/22/2009 ELECTRIC - FINAL Denied 1) COMPLETE WATER HEATER INSTALLATION AND FURNACE
03/30/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEW PANEL NOT GROUNDED
2) INSTALL GROUND ROD SYSTEM
3) BOND GAS LINE
4) PROVIDE PROOF OF CARPORT ENCLOSURE AND DINING ROOM KITCHEN EXTENSION
5) MISSING LIGHT FIXTURES THROUGHOUT
6) MISSING SMOKE ALARMS BEDROOMS AND HALLWAYS
7) REPLACE BATH FIXTURES WITH OUTLETS NOT GFCI PROTECTED
8) RECOMMEND CODE COMPLIANT PERMIT