Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2009 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 11/25/2009 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* 1) BOND GAS LINE 2) LABEL CIRCUITS MAIN PANEL 3) RELOCATE SMOKE ALARMS MAY NOT BE WITHIN 36" FORCED AIR REGISTERS, RELOCATE 6"-12" FROM CEILING |
|
| 04/01/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GFCI RECEPTS REQUIRED KITCHEN 2) SMOKE DETECTORS EACH BEDROOM AND ENTRY TO BEDROOMS 3) EXPOSED ROMEX IN LAUNDRY ROOM 4) KITCHEN SHELF COVERING SUB PANEL COVER REMOVE FOR INSPECTION, IF SUB PANEL IS AN UNGROUNDED SYSTEM, ALL GROUND TYPE WALL RECEPTS TO BE SAME OR ON GFCI PROTECTION 5) VERIFY GROUND SYSTEM CU TO IRON PIPE CONNECTION AT FRONT WALL NO DIELECTRIC UNION 6) AL TO CU. GRD. A/C UNIT |
|
| 03/27/2009 | ELECTRIC - RECONNECT | Denied | NO KEY IN LOCK BOX PLEASE RECALL |