Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/31/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 08/26/2009 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) RECALL AFTER POWER IS RESTORED |
|
| 04/01/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED SMOKE DETECTORS IN EACH BEDROOM 2) NEED GFI PROTECTION AT KITCHEN COUNTER OUTLETS 3) HAVE LICENSED ELECTRICIAN EVALUATE THE SYSTEM AND CORRECT WHERE NEEDED, IE-, EXPOSED WIRING NOT IN CONDUIT, DBL TAPED CIRCUITS IN PANEL (POSSIBLY REQUIRING A SERVICE UPGRADE), OVER FUSED CIRCUITS IN PANEL AND POSSIBLE 3 PRONG OUTLETS ON 2 WIRE CIRCUIT 4) CONNECT WATER HEATER FLUE |