Permit: T09EL00510

Parcel: 134231650


Addresses:

6667 E SCARLETT ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
06/12/2009 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
03/18/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL BAR/GRILLES ON BEDROOM WINDOWS REMOVE OR BRING UP TO CODE. SEE CODE SECTION CITY ADMENDMENTS
2) ALL RECEPTS GRD TYPE NOT TO BE ON TWO WIRE UNDERGROUNDED SYSTEMS
3) REAR ADDITIONS ARE THEY (PERMITTED) AND INSPECTED, LOOKS LIKE BRICK VENEER WALL HAS SEPERATED FROM STRUCTUAL WALL
4) LABEL ALL CIRCUITS IN SERVICE PANEL UNABEL TO I.D. BOTH 50/50 CIRCUITS
5) BREAKERS IN PANEL TO MATCH, SAME MANUFACTURER OF PANEL
6) 4 SQUARE RECEPT IN FRONT BEDROOM CEILING
7) TEP LINES FROM POLE TO POINT OF ATTACHMENT ROOF, INSULATORS NOT ATTACHED, NEED NEW POWER LINE AND POINT OF ATTACHMENT, ARRANGE THRU TEP