Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09EL00494

Parcel: 120083950

Inspection Status: Partial Approval

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/20/2009 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) POWER RELEASED TO UNIT #1 ONLY
2) SEPERATE PERMIT MAYBE REQUIRED FOR UNIT #2
3) SITE PLAN ON RECORD DOES NOT SHOW REAR ADDITION AND FRONT ENCLOSURE
03/19/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSPECTION FOR UNIT #1 ONLY:
1) POST ADDRESS #126 VISIBLE FROM STREET
2) DRIP LEG WATER HEATER EXTEND RELIEF LINE 6"-24" FROM GROUND
3) MISSING 3 SELF TAPPING SCREWS STAND TO B-VENT CONNECTION
4) PROVIDE PROPER STAND
03/13/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT 1:
1) POST ADDRESS AND UNIT NUMBERS VISIBLE FROM STREET
2) WATER HEATER NOT TO CODE
3) SECURE EXTERIOR GFCI BOX TO BLDG
4) SECURE ALL ADDED CONDUIT TO BLDG
5) ALL BREAKERS MUST BE CUTTLER HAMMER, REMOVE OR REPLACE MIXED BREAKERS MAIN PANEL
6) SMOKE ALARM HALLWAY
7) DAMAGED COVER PLACES THROGHOUT
-------------------------------------------------------------------------------------------------
UNIT 2:
1) PROVIDE WEATHERED EXTERIOR FIXTURE
2) LABEL ALL CIRCUITS MAIN SERVICE PANEL
3) MISSING COVER PLATES THROUGHOUT
4) PROVIDE COMBUSTION RELIEF TO EXTERIOR AT WATER HEATER ROOM
5) UNSAFE WIRING AT LAUNDRY DISCONNECT BOX, HAVE ELECTRICIAN REPAIR TO CODE
6) PROVIDE PROOF OF PERMIT ALL ADDITIONS
7) SMOKE ALARMS BEDROOM AND HALLWAY
8) BEDROOM WINDOW DAMAGED DOES NOT MEET EGRESS REQUIREMENTS 5:79 SQUARE FT