Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/06/2009 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 03/02/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE ACCESS TO ROOF LADDER-SHALL EXTEND 30" ABOVE PARAPET 2) POST ADDRESS 3) VACUUM BREAKER MISSING AT EXTERIOR HOSE BIBS 4) REPLACE BROKEN OUTLETS AND COVERS 5) GFI PROTECTED OUTLETS REQUIRED IN BATHROOM AND KITHCEN 6) DAMP PROOF AND LIGHT TRIM REQUIRED AT BATHROOM ABOVE TUB 7) SMOKE ALARMS REQUIRED IN BEDROOMS AND HALL 8) PROTECT EXPOSED ROMEX UNDER SINK IN FUTURE DISHWASHER SPACE 9) REMOVE COPPER FLEX FROM PTR LINE, DISCHARGE DOWNWARD 10) REPAIR/REPLACE EXTERIOR OUTLETS |