Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T09EL00356
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/15/2009 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
02/24/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED GROUND RODS AS MAIN WATER SUPPLY LINE HAS BEEN CHANGED TO PLASTIC 2) WIRE IN L/R CEILING NEEDS TO BE TERMINATED IN AN ELECTRIC BOX WITH FIXTURE OR BLANK COVER AND BEDROOMS 3) NEED OPERABLE SMOKE DETECTORS IN HALLWAY AND ALL BEDROOMS AT LEAST 3' FROM HEAT/COOL DUCT REGISTERS 4) NEED TO CONFIRM THAT KITCHEN COUNTER RECEPTS ARE GFI 5) NEED BLANK COVER OVER KITCHEN SINK LIGHT |