Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/27/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 02/20/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. DOUBLE LUGGED 30 AMP CIRCUIT WITH 12-2 HAZARDOUS ROMEX NOT PROTECTED FROM PHYSICAL DAMAGE 2. PROVIDE PROOF OF PERMIT REAR ADDITION LAUNDRY ROOM DETACHED WITH ELECTRICAL & PLUMBING 3. EXTEND PRESSURE RELIEF LINE 6"-24" FROM GROUND 4. MISSING REAR LIGHT FIXTURE 5. MISSING LIGHT FIXTURES AND COVER PLATES THROUGOUT 6. AT LEAST 1 WINDOW EACH BEDROOM MUST OPERATE PROPERLY FOR EMERGENCY EGRESS 7. SMOKE DETECTORS REQUIRED ALL BEDROOMS & HALLWAYS 8. 2 WIRE & OUTLETS WITH GROUND MIXED THROUGHOUT 9. REMOVE ROMEX TO SHOWER HEAD 10. PROVIDE PROOF A/C OR ROOFTOP UNIT |