Permit: T09EL00329

Parcel: 132180010


Addresses:

1226 E MISSOURI ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
03/02/2009 ELECTRIC - RECONNECT Approved
02/25/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROTECT ROMEX IN STORAGE FOAM PHYSICAL DAMAGE UNDER 8' HAZARDOUS WIRING STORAGE
2) RELOCATE SMOKE DETECTORS CANNOT BE WITHIN 36" FROM FORCED AIR REGISTERS 6"-12" FROM CEILING
3) GFCI PROTECT EXTERIOR OUTLETS-220 NOT IN APPROVED BOX
4) 2 WIRE CIRCUIT OUTLETS CHANGED TO GROUNDED OUTLETS-GFCI PROTECT HEAD OF ALL CIRCUITS
5) MIXED SQUAR D BREAKER IN FEDERAL PACIFIC PANEL OR RESTORE TO ORIGINAL 2 WIRE OUTLETS
6) BAD CONNECTION LIQUID TIGHT AT PANEL
7) PROVIDE PROOF PERMIT A/C FURNACE REPLACEMENT
02/23/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/20/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*