Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2009 | ELECTRIC - RECONNECT | Approved | ||
| 02/25/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROTECT ROMEX IN STORAGE FOAM PHYSICAL DAMAGE UNDER 8' HAZARDOUS WIRING STORAGE 2) RELOCATE SMOKE DETECTORS CANNOT BE WITHIN 36" FROM FORCED AIR REGISTERS 6"-12" FROM CEILING 3) GFCI PROTECT EXTERIOR OUTLETS-220 NOT IN APPROVED BOX 4) 2 WIRE CIRCUIT OUTLETS CHANGED TO GROUNDED OUTLETS-GFCI PROTECT HEAD OF ALL CIRCUITS 5) MIXED SQUAR D BREAKER IN FEDERAL PACIFIC PANEL OR RESTORE TO ORIGINAL 2 WIRE OUTLETS 6) BAD CONNECTION LIQUID TIGHT AT PANEL 7) PROVIDE PROOF PERMIT A/C FURNACE REPLACEMENT |
|
| 02/23/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/20/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |