Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2009 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* 1) CALL FOR FINAL WHEN POWER IS TURNED ON |
|
| 03/09/2009 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection :* 1) NEED BEAM SUPPORT FOR PORCH ROOF 2) NEED 30/30 FOR H20 HTR (WESTING HOUSE PANEL ALL BREAKERS TO MATCH) 3) NEED 2 POLE 50/50 4) NEED 2 POLE 30/30 FOR H20 HTR 5) NEED 2 20 AMP OR 2 WAFFER 20/20 GENERAL LIGHTING #12 WIRE |
|
| 02/06/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTEND PRESSURE RELIEF LINE 6"-24" FROM GROUND WATER HEATER 2) BLANK COVER OR SPARE BREAKER OPENING IN PANEL 3) MIXED BREAKERS IN PANEL MUST ALL MATCH SERVICE PANEL TYPE 4) A LEAST ONE BEDROOM WINDOW BARS MUST OPERATE WITHOUT SEPERATE TOOLS FOR EGRESS 5) NEW CIRCUITS ADDED TO BEDROOM REQUIRE PERMIT TO INCLUDE ALL ELECTRICAL WORK DONE AND LAUNDRY ROOM 6) ALL EXPOSE ELECTRICAL INTERIOR MUST BE PROTECTED FROM PHYSICAL DAMAGE 7) REMOVE LAUNDRY ENCLOSURE OR PERMIT 8) SMOKE DETECTOR ALL BEDROOMS 9) MIDDLE BEDROOM LACKS PROPER EGRESS |
|
| 02/05/2009 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : NO ACCESS TO INSIDE PLEASE CALL FOR REINSPECTION |