Permit: T09EL00212

Parcel: 118040260

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
03/10/2009 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
1) CALL FOR FINAL WHEN POWER IS TURNED ON
03/09/2009 ELECTRIC - RECONNECT Not ready for Inspection IVRS - Inspection :*
1) NEED BEAM SUPPORT FOR PORCH ROOF
2) NEED 30/30 FOR H20 HTR (WESTING HOUSE PANEL ALL BREAKERS TO MATCH)
3) NEED 2 POLE 50/50
4) NEED 2 POLE 30/30 FOR H20 HTR
5) NEED 2 20 AMP OR 2 WAFFER 20/20 GENERAL LIGHTING #12 WIRE
02/06/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXTEND PRESSURE RELIEF LINE 6"-24" FROM GROUND WATER HEATER
2) BLANK COVER OR SPARE BREAKER OPENING IN PANEL
3) MIXED BREAKERS IN PANEL MUST ALL MATCH SERVICE PANEL TYPE
4) A LEAST ONE BEDROOM WINDOW BARS MUST OPERATE WITHOUT SEPERATE TOOLS FOR EGRESS
5) NEW CIRCUITS ADDED TO BEDROOM REQUIRE PERMIT TO INCLUDE ALL ELECTRICAL WORK DONE AND LAUNDRY ROOM
6) ALL EXPOSE ELECTRICAL INTERIOR MUST BE PROTECTED FROM PHYSICAL DAMAGE
7) REMOVE LAUNDRY ENCLOSURE OR PERMIT
8) SMOKE DETECTOR ALL BEDROOMS
9) MIDDLE BEDROOM LACKS PROPER EGRESS
02/05/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
NO ACCESS TO INSIDE
PLEASE CALL FOR REINSPECTION