Permit: T09EL00190

Parcel: 118200290


Addresses:

316 W 23RD ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
03/30/2009 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
02/04/2009 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. HAZARDOUS CONNECTION LIQUID TIGHT AT CONDENSOR DISCONNECT. SECURE TO BUILDING.
2. PERMIT ADDED CIRCUITS TO PANEL OR OMIT
3. WHITE LEADS HOT TO 30 AMP. BREAKER MUST BE
BLACK OR RED
4. LABEL ALL CIRCUITS
5. MISSING COVER PLATES THROUGHOUT
6. GFCI PROTECT KITCHEN COUNTER OUTLET AND BATH OUTLETS
7. RELOCATE BEDROOM SMOKE DETECTORS 6"-12" BELOW CEILING
8. PROVIDE WORKING SMOKE DETECTOR HALLWAYS
9. PROVIDE WEATHERED FIXTURES EXTERIOR