Permit: T09EL00179

Parcel: 120092670


Addresses:

408 E RODEO DR

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
02/20/2009 ELECTRIC - FINAL Approved
02/11/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 36" CLEARANCE REQUIRED IN FRONT OF SERVICE PANEL
2) FLEX GAS LINE MAY NOT PENETRATE CABINET MUST BE HARD PIPED. EXTEND RELIEF LINE 6"-24" FROM GROUND. SECURE B-VENT
3) PROVIDE PROOF ALL ADDITIONS PERMITTED, ADDITION TO PROPERTY LINE EAST AND ADDITION TO REAR
4) HAZARDOUS ELECTRICAL REAR ADDITION EXTERIOR
5) PROVIDE SECONDARY GROUND ROD 6'
6) BOND GAS AND WATER LINES