Case: T09DV07013

Parcel: 106121450

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T09DV07013

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Approved

Date Description Inspector Results Comments
05/07/2011 INSP - FOLLOW UP CODE ENFORCE Approved CLOSE OUT CASE.
03/07/2011 INSP - FOLLOW UP CODE ENFORCE Approved MET W/MHP MGR DISCUSSED THE PERMIT AND THE CASE. NEW MGR IS WORKING AT GETTING THE WORK COMPLETED AND ALSO MANAGED TO DRAW UP A NEW SITE PLAN AND SHE NOW KNOWS SHE NEEDS TO GET THE CITY'S APPROVAL FOR THE NEW SITE PLAN.
03/07/2011 INSP - FOLLOW UP CODE ENFORCE Approved MET W/MHP MGR DISCUSSED THE PERMIT AND THE CASE. NEW MGR IS WORKING AT GETTING THE WORK COMPLETED AND ALSO MANAGED TO DRAW UP A NEW SITE PLAN AND SHE NOW KNOWS SHE NEEDS TO GET THE CITY'S APPROVAL FOR THE NEW SITE PLAN.
12/22/2010 INSP - FOLLOW UP CODE ENFORCE Approved DSD DENIED ~
1) VENTLESS (GAS FIRED) HEATING APPLIANCE
NOT TO BE USED AS PRIMARY HEAT SOURCE
FU IN 30 DAYS
12/09/2010 INSP - FOLLOW UP CODE ENFORCE Approved TRAILER PARK MGR OBTAINED A PERMIT TO INSTALL A HEATER INTO UNIT # 102 PERMIT #T10EM00703 FU IN 2 WKS
11/17/2010 INSP - FOLLOW UP CODE ENFORCE Approved MET W/MHP MGR REGARDING THE INSTALLATION OF THE HEATING SYSTEM TO THE VACANT UNIT. VIOLET WILL HAVE THE UNIT PERMIT COMPLETED BY NEXT FRIDAY. FOLLOW UP 12/3/10
09/30/2010 INSP - FOLLOW UP CODE ENFORCE Approved MET W/MAINT STAFF WALKED SITE.. UNIT IS VACANT STILL, UNIT #102 ADDED CIRCUITS REMOVED, UNIT RETURNED BACK TO A 2 PRONG SYSTEM, ROOF REPAIRED, WINDOW REPLACED WITH WINDOW THAT OPENS AND CLOSES... RISER NOLONGER HAS A GAP. SPOKE TO MHP MGR V AND STATED UNIT MUST BE KEPT VACANT UNTIL THE HEATING SYSTEM IS ADDED IN TO THE UNIT. MGR MENTIONED THEY WERE GOING TO HAVE A LIC PLUMBER INSTALL THE HEATING SYSTEM UNDER PERMIT AND WOULD KEEP IT VACANT UNTIL IT IS COMPLETED OUT.
08/24/2010 INSP - FOLLOW UP CODE ENFORCE Approved MET W/MHP MGR REGARDING THE STATUS OF THE CASE. UNIT STILL VACANT: NEED TO REMOVE ADDED ELECTRICAL CIRCUITS IN 102 AND MAKE ALL 3 PRONG ELECTRICAL OUTLETS 2 PRONG OUTLETS AS UNIT WAS ORGINALLY DESIGNED. VERIFY ROOF NO LONGER LEAKS... FU 30 DAYS.
07/22/2010 INSP - FOLLOW UP CODE ENFORCE Approved Met w/Violet at 3333 gap was addressed. Also took time to sit down and discuss the case violation by violation to see where we stood in abating all the violations. The outstanding violation are in unit #102 the added circuits and the leak in the ceiling. Also discussed bldg #111. Stressed the importance of calling in for inspections on the permit. Also discussed the importance of having a site plan that matches what is actually there on the site.
06/16/2010 INSP - FOLLOW UP CODE ENFORCE Approved NO LUCK TRYING TO GET MH PARK TO REPAIR RISER/METER GAP... WELL SEND AN NOV FOCUSED ONLY ON THIS ISSUE...
05/24/2010 INSP - FOLLOW UP CODE ENFORCE Approved FOLLOWED UP ON RISER. RISER IS STILL NOT FIXED, GAP IS STILL VISIBLE...
05/04/2010 INSP - FOLLOW UP CODE ENFORCE Approved DISCUSSED W/RS REGARDING THE RESPONSE BACK FROM DSD. DSD DIDN'T FEEL THE RISER WAS INCLUDED AS PART OF THE UPGRADE TO THE ELECTICAL SYSTEM. SO THE BLDG INSPECTOR DID NOT INSPECT THE RISER AS PART OF THE ELECTRICAL SYSTEM. WELL RE-ADDRESS CONCERN WITH THE PROPERTY MANAGER SG.
05/03/2010 INSP - FOLLOW UP CODE ENFORCE Approved Rechecked electrical riser. Gap still exist will discuss w/RS about case.
01/28/2010 INSP - FOLLOW UP CODE ENFORCE Approved CHECKED ELECTRICAL, STILL FOUND MISSING FUSES AND DBL LUGGING, AND DISCONNECT UNIT.L CHARGE 75$ FEE FOR NOT ABATEING AND ALSON SEND ADDENDUM NOV TO OWNER NOTING THE MISSING FUSES ON DISCONNECT BOXES